| UOM | EA | Seal Material | Fluorocarbon |
| Actuation Type | Electrical | Configuration | Normally Closed, Pressure Compensated |
| Flow Rate | 4, 6 GAL/MIN, 15, 23 L/MIN | Override Functionality | N/A |
| Current | Max: 1.15 @ 12 VDC, 1.58 @ 12 VDC, 0.58 @ 24 VDC, 0.79 @ 24 VDC A | Cavity Size | C08-3 |
| Minimum Operating Temperature | -15 °F | Flow Direction | Top to Side (3 - 2) |
| Power Consumption | 14, 19 W | Operating Temperature | -26 to +204 °C |
| Filter Efficiency Rating | ISO 4406 18/16/13, SAE Class 4 | Flow Rate Accuracy | Up to 20% |
| Actuation Type | Electrical | Configuration | Normally Closed, Pressure Compensated |
| Coil Nut Tightening Torque | 4.1 Nm | Weight | 0.17 lb |
| Maximum Operating Pressure | 3000 psi | Variation of Opening Point | 25% of Input Signal |
| Flow Rate | 15, 23 L/min | Maximum Kinematic Viscosity | 45-2000 SSU (6 to 420 cSt) |
| For Fluid Type | Mineral-based or synthetic hydraulic fluids | Frequency | 100-400 Hz |
| Coil Type | 1/2" Super Coil | Division | Hydraulic Cartridge Systems Division |
| Connection Type | N/A | Body Material | N/A |
| Division | Hydraulic Systems Division | Installation Torque | 27 Nm |
| Operation Type | Solenoid operated | Maximum Inlet Pressure Rating | 210 bar |
| Function | Proportional Flow Control/Regulator | Wire Mesh Screen Included | Yes |
| Connection Size | N/A | Variation of Closing Point | N/A |
| Minimum Pressure Differential | 13.8, 20.7 bar | Hysteresis | < 3%, < 10% |
| Maximum Operating Temperature | +400 °F | Seal Material | Fluorocarbon |
| Valve Material | All parts steel. All operating parts hardened steel | Leak Rate | 570 @ 3000 PSI (210 BAR) cm3/min |
| Maximum Flow Rate | 15, 23 L/min | | |