- Availability & Price
- Search SKU
Filter by attributes
- Bypass Valve Pressure Rating
- Filter Element Type
- Flow Rate
- Indicator Type
- Options
- Port Connection Type
- Seal Material
Filter by manufacturer
BGT NA
*PRODUCT IMAGE IS REPRESENTATIVE PROVIDED BY THE MANUFACTURER. DO NOT MAKE BUYING DECISIONS SOLEY BASED ON THE IMAGE. PLEASE VERIFY SPECIFICATIONS MEET YOUR REQUIREMENTS.
BGT Filters feature Parker’s exclusive Magnetic Pre-filtration core which collects ferromagnetic particles from fluid upstream of the filter element. This feature alone could save hundreds of dollars a year by protecting costly equipment from increased wear and malfunction by assuring that the fluid is as pure as possible when it leaves the filter. Even during bypass due to cold start up, ferrous contaminant is collected by the magnetic core, a feature of importance on any fluid power system.
Fluid flows through the inlet port into an enlarged area which reduces fluid velocity. Inlet flow does not impinge on the element. Filtration begins with magnetic pre-filtration of ferromagnetic particles in the full fluid flow upstream of the element, not downstream or in the reservoir. Built-in or system generated ferromagnetic wear debris (even particles smaller than the element rating) are collected by the high strength (3.0K Gauss) magnetic column. This results in extended element and oil life and reduced maintenance and downtime, which reduces overall operating cost.
Fluid passes through the element in an inside-to-outside direction, collecting particles inside the filter cartridge. This eliminates reinjection of contaminant during element change. Clean fluid then returns to the reservoir through the diffusor which prevents fluid aeration.
Normal return line filters, that flow outside-to-inside, allow contaminated fluid to drain back into the reservoir when the element is serviced. Simplified bypass design and location prevents flushing previously collected contaminant back into the system. Magnetic filtration occurs even during bypass. All potential leakage paths are o-ring sealed to eliminate bypass leakage that occurs in loose fitting valve assemblies.
BGT Filters are available with disposable elements of several contamination class levels for use in all common fluids. Optional accessories include visual and electric warning indicators that assure proper element service.
Product Features:
• Pre-filtration by means of a magnet column
• Filter heads with multiple ports available
• Inside-out flow
• Full flow bypass with low hysteresis
• Maximum pressure 150 PSI/10 bar. Maximum flow 640 GPM/2400 LPM.
• Patented elements safeguard filtration quality
Typical Applications:
• Mobile cranes
• Excavators
• Deck cranes
• Firefighting equipment
• Hydraulic presses
• Waste balers
• Industrial power units
• Fork lift trucks
Read More...Fluid flows through the inlet port into an enlarged area which reduces fluid velocity. Inlet flow does not impinge on the element. Filtration begins with magnetic pre-filtration of ferromagnetic particles in the full fluid flow upstream of the element, not downstream or in the reservoir. Built-in or system generated ferromagnetic wear debris (even particles smaller than the element rating) are collected by the high strength (3.0K Gauss) magnetic column. This results in extended element and oil life and reduced maintenance and downtime, which reduces overall operating cost.
Fluid passes through the element in an inside-to-outside direction, collecting particles inside the filter cartridge. This eliminates reinjection of contaminant during element change. Clean fluid then returns to the reservoir through the diffusor which prevents fluid aeration.
Normal return line filters, that flow outside-to-inside, allow contaminated fluid to drain back into the reservoir when the element is serviced. Simplified bypass design and location prevents flushing previously collected contaminant back into the system. Magnetic filtration occurs even during bypass. All potential leakage paths are o-ring sealed to eliminate bypass leakage that occurs in loose fitting valve assemblies.
BGT Filters are available with disposable elements of several contamination class levels for use in all common fluids. Optional accessories include visual and electric warning indicators that assure proper element service.
Product Features:
• Pre-filtration by means of a magnet column
• Filter heads with multiple ports available
• Inside-out flow
• Full flow bypass with low hysteresis
• Maximum pressure 150 PSI/10 bar. Maximum flow 640 GPM/2400 LPM.
• Patented elements safeguard filtration quality
Typical Applications:
• Mobile cranes
• Excavators
• Deck cranes
• Firefighting equipment
• Hydraulic presses
• Waste balers
• Industrial power units
• Fork lift trucks
| Action | SKU | Availability | Partner Available | Price | UOM | Seal Material | Options | Filter Element Type | Indicator Type | Port Connection Type | Bypass Valve Pressure Rating | Flow Rate | Options | Seal Material | Bypass Valve Pressure Rating | Housing Material | Product Type | Filter Element Type | Pressure Rating | Division | Maximum Operating Temperature | For Fluid Type | Port Type | Weight | Indicator Pressure Setting | Product Style | Indicator Type | Compatible Element | Mounting Style | Flow Rate |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| BGT1710QBVEF481 | Backordered | Backordered | POR | EA | Nitrile | None | 10Q Microglass | Electrical Differential Indicator | 3inch SAE flange, Code 61 | 22 psi (1.5 bar) | 530 gpm (2000 lpm) | None | Nitrile | 1.5 bar | Aluminum Alloy | Hydraulic Filter | 10Q microglass | 150 psi | Engine Mobile Hydraulic and Fuel Filtration Division | 107.0 °C | Mineral, Petroleum and Polyalphaolefin (PAO) based fluids | 3inch SAE flange, Code 61 | 37.2 kg | 1.2 bar | Hydraulic Filter | Visual Differential Indicator | 937772Q | Tank Top | 2400.0 L/min | |
| BGT1720QBPEF481 | Backordered | Backordered | $3,547.77/each | EA | Nitrile | None | 20Q Microglass | Plugged Indicator Port | 3inch SAE flange, Code 61 | 22 psi (1.5 bar) | 634 gpm (2400 lpm) | None | Nitrile | 1.5 bar | Aluminum Alloy | Hydraulic Filter | Cartridge | 150 psi | Engine Mobile Hydraulic and Fuel Filtration Division | 225.0 °F | Mineral, Petroleum and Polyalphaolefin (PAO) based fluids | 3inch SAE flange, Code 61 | 82 lb | 18 psi | Hydraulic Filter | Plugged Indicator Port | 937805Q | Tank Top | 634.0 Gal/min |