RDH083K15 - Direct Acting Differential Area Relief Valves

Parker’s direct acting differential area relief valves are for fast response intermittent applications and work up to 380 bar (5500 psi) and 151 lpm (40 gpm). These valves have lower leakage rates and pressure rise than standard direct acting reliefs.
Manufacturer: Parker
Availability:
Backordered
Estimated Lead Time: 71 days
Partner Available:Backordered
SKU RDH083K15
$73.52/each
Ship to
*
*
Shipping Method
Name
Estimated Delivery
Price
No shipping options
Products specifications
Attribute nameAttribute value
UOMEASeal MaterialNitrile
Adjustment MechanismKnobMounting TypeScrew in cartridge valve
Cracking PressureN/AFlow Rate12 GAL/MIN, 45 L/MIN
Maximum Inlet Pressure Rating5500 PSI, 380 BARPressure Control Range100-1500 PSI, 6.9-103.5 BAR
Standard Setting Pressure750 PSI, 51.7 BAROperating Temperature-34 to +121 °C
Flow Rate12 Gal/minActuation TypePressure Sensing
ConfigurationDifferential Area Relief, Differential Relief w/Reverse Flow CheckMaximum Kinematic Viscosity45-2000 SSU (6 to 420 cSt)
Pressure Control Sensitivity15 per turn barBody MaterialN/A
Filter Efficiency RatingISO 4406 18/16/13, SAE Class 4Weight0.43 lb
Maximum Operating Pressure5500 psiReseat Pressure75% of pressure setting
DivisionHydraulic Systems DivisionInstallation Torque31 Nm
Operation TypeAutomaticStandard Setting Pressure51.7 bar
For Fluid TypeMineral-based or synthetic hydraulic fluidsMaximum Flow Rate45 L/min
Minimum Operating Pressure380 barMaximum Operating Temperature+250 °F
Valve MaterialAll parts steel. All operating parts hardened steelSeal MaterialNitrile
Maximum Pressure Setting103.5 barLeak Rate10 @ 75% Crack Pressure drops/min
Maximum Inlet Pressure Rating5500 psiFunctionDirect Acting
Maximum Tank Pressure350 barAdjustment MechanismKnob
Cavity SizeC08-2Cracking PressureN/A psi
Minimum Operating Temperature-34 °CMounting TypeScrew in cartridge valve
Port Thread SizeN/APressure Control Range6.9-103.5 bar
Product resources