C02A3CZN - Direct Acting Pressure Reducing Relieving Valves

Parker’s direct acting reducing & relieving valves are used in intermittent duty applications where specific functions require reduced and regulated pressure. Capable of flows up to 56 lpm (13 gpm) and pressures up to 420 bar (6000 psi).
Manufacturer: Parker
Availability:
Backordered
Estimated Lead Time: 133 days
Partner Available:Backordered
SKU C02A3CZN
$249.81/each
Ship to
*
*
Shipping Method
Name
Estimated Delivery
Price
No shipping options
Products specifications
Attribute nameAttribute value
UOMEASeal MaterialNitrile
Adjustment MechanismScrewMaximum Inlet Pressure Rating6000 PSI, 420 BAR
Flow Rate5 GAL/MIN, 20 L/MINPressure Control Range73-580 PSI, 5-40 BAR
Pressure Control Range5 to 40 barOperating Temperature-34 to 121 °C
Pressure Control Sensitivity5.6 bar Per TurnFlow Rate20 L/min
Maximum Kinematic Viscosity45-2000 SSU (6 to 420 cSt)ConfigurationPressure Reducing/Relieving
Maximum Operating Pressure6000 psiBody Materialn/a
Actuation TypePressure SensingFilter Efficiency RatingISO 4406 18/16/13
Maximum Pressure Differentialn/aWeight0.44 lb
Installation Torque40 NmStandard Setting Pressure20 bar
DivisionMobile Hydraulic Systems Division EuropeOperation TypeAutomatic
Maximum Flow Rate20 L/minFor Fluid TypeMineral-based Hydraulic Fluids
Maximum Drain Flow Raten/aSeal MaterialNitrile
Valve MaterialHardened Steel (all operating parts)Maximum Operating Temperature121 °C
Maximum Pressure Setting40 barFunctionDirect Acting
Maximum Tank Pressure6000 psiMaximum Inlet Pressure Rating6000 psi
Adjustment MechanismScrewCavity SizeC08-3
Minimum Operating Temperature-34 °CMounting TypeScrew-in Cartridge
Product resources