• Availability & Price
  • Search SKU
Filter by attributes
  • Maximum Flow Rate
  • Maximum Operating Pressure
  • Mounting Type
  • Size
More Filters...
Filter by manufacturer

Pilot Operated Directional Control Valve - D61VW Series

Picture for category Pilot Operated Directional Control Valve - D61VW Series

*PRODUCT IMAGE IS REPRESENTATIVE PROVIDED BY THE MANUFACTURER. DO NOT MAKE BUYING DECISIONS SOLEY BASED ON THE IMAGE. PLEASE VERIFY SPECIFICATIONS MEET YOUR REQUIREMENTS.

Parker’s D61VW directional control valves are available in 2 or 3-position. They are manifold or subplate mounted valves which conform to NFPA’s D08, CETOP 8 mounting patterns.

Markets:
• Entertainment Automation
• Factory Automation
• Lumber & Wood
• Machine Tools
• Marine
• Material Handling
• Miscellaneous Industrial
• Miscellaneous Manufacturing
• Miscellaneous Processing
• Molding
• Oil & Gas
• Other Natural Resources
• Packaging Machinery
• Plastic Packaging
• Power Generation
• Primary Metal Refining/Process
• Printing and Marking Equipment
• Rubber & Tire Processing
• Vehicle Assembly Facilities

Features/Benefits:
• Explosion proof available
• Low pressure drop design
• Fast response option available
• Hardened spools provide long life
• No tools required for coil removal
• Wide variety of voltages and electrical connections available

Applications:
• Suitable for general hydraulic applications
Read More...
View as Grid List
Sort by
Display per page
ActionSKUAvailabilityPartner AvailablePriceUOMMounting TypeSizeMaximum Flow RateMaximum Operating PressureMounting TypeMinimum Operating TemperaturePilot Inlet / Drain LocationsWeightMaximum Operating PressureBody MaterialSpool CodeActuation TypeDivisionSpool PositionMaximum Flow RateConnection TypeValve TypeAdditional OptionsPower Supply VoltageCoil Specifications MetOptionsSeal MaterialSolenoid OptionMaximum Operating Temperature
D61VW001D1NYCF
Backordered
Backordered
POR
EASubplateNFPA D08, CETOP8, DIN NG25, Low Flow, D03 Pilot35-100 GPM3000 psi/205 barSubplate-4 °FInternal Pilot / External Drain26.6 lb3000 psiGray Iron4-WayHydraulic PressureHydraulic Valve Systems DivisionDouble Solenoid100 Gal/minLeadwire Conduit BoxPilot Operated Directional Control ValveConsult catalog for additional features.120/60 - 110/50 VACOmit to Standard ValveOmit - No OptionsNitrileLow Watt140 °F
D61VW001D1NYGF5
Backordered
Backordered
POR
EASubplateNFPA D08, CETOP8, DIN NG25, Low Flow, D03 Pilot35-100 GPM3000 psi/205 barSubplate-4 °FInternal Pilot / External Drain12.1 kg207 barGray Iron3-PositionHydraulic PressureHydraulic Valve Systems DivisionDouble Solenoid100 Gal/minPlug-in Conduit BoxPilot Operated Directional Control ValveConsult catalog for additional features.120/60 - 110/50 VACOmit to Standard ValveSignal LightsNitrileLow Watt140 °F
D61VW001D2NYCF
Backordered
Backordered
POR
EASubplateNFPA D08, CETOP8, DIN NG25, Low Flow, D03 Pilot35-100 GPM3000 psi/205 barSubplate-4 °FExternal Pilot / External Drain26.6 lb3000 psiGray IronAll Ports BlockedHydraulic PressureHydraulic Valve Systems DivisionDouble Solenoid100 Gal/minLeadwire Conduit BoxPilot Operated Directional Control ValveConsult catalog for other available features120/60 - 110/50 VACOmit to Standard ValveOmit - No OptionsNitrileLow Watt140 °F
D61VW001D3NJW
Backordered
Backordered
$1,673.28/each
EASubplateNFPA D08, CETOP8, DIN NG25, Low Flow, D03 Pilot35-100 GPM3000 psi/205 barSubplate-4 °FInternal Pilot w/ Check / External Drain12.1 kg207 barGray Iron3-PositionHydraulic PressureHydraulic Valve Systems DivisionDetent100 Gal/minDIN w/o PlugPilot Operated Directional Control ValveConsult catalog for additional features.24 VDCOmit to Standard ValveOmit - No OptionsNitrileOmit - High Watt140 °F
D61VW001D3NYCF
Backordered
Backordered
POR
EASubplateNFPA D08, CETOP8, DIN NG25, Low Flow, D03 Pilot35-100 GPM3000 psi/205 barSubplate-4 °FInternal Pilot w/ Check / External Drain12.1 kg3000 psiGray IronAll Ports BlockedHydraulic PressureHydraulic Valve Systems Division2-Position100 Gal/minLeadwire Conduit BoxPilot Operated Directional Control ValveConsult catalog for additional features.120/60 - 110/50 VACOmit to Standard ValveOmit - No OptionsNitrileLow Watt140 °F
D61VW001D4NJC
Backordered
Backordered
$1,428.00/each
EASubplateNFPA D08, CETOP8, DIN NG25, Low Flow, D03 Pilot35-100 GPM3000 psi/205 barSubplate-4 °FInternal Pilot / Internal Drain26.6 lb3000 psiGray IronAll Ports BlockedHydraulic PressureHydraulic Valve Systems DivisionDetent100 Gal/minLeadwire Conduit BoxPilot Operated Directional Control ValveConsult catalog for other available features24 VDCOmit to Standard ValveOmit - No OptionsNitrileOmit - High Watt140 °F
D61VW001D4NJC20
Backordered
Backordered
$1,499.40/each
EASubplateNFPA D08, CETOP8, DIN NG25, Low Flow, D03 Pilot35-100 GPM3000 psi/205 barSubplate-4 °FInternal Pilot / Internal Drain12.1 kg207 barGray IronAll Ports BlockedHydraulic PressureHydraulic Valve Systems DivisionDetent100 Gal/minLeadwire Conduit BoxPilot Operated Directional Control ValveConsult catalog for additional features.24 VDCOmit to Standard ValveFast ResponseNitrileOmit - High Watt140 °F
D61VW001D4NJG5
Backordered
Backordered
$1,512.00/each
EASubplateNFPA D08, CETOP8, DIN NG25, Low Flow, D03 Pilot35-100 GPM3000 psi/205 barSubplate-4 °FInternal Pilot / Internal Drain12.1 kg207 barGray Iron4-WayHydraulic PressureHydraulic Valve Systems Division2-Position100 Gal/minPlug-in Conduit BoxPilot Operated Directional Control ValveConsult catalog for additional features.24 VDCOmit to Standard ValveSignal LightsNitrileOmit - High Watt140 °F
D61VW001D4NJW
Backordered
Backordered
$1,464.12/each
EASubplateNFPA D08, CETOP8, DIN NG25, Low Flow, D03 Pilot35-100 GPM3000 psi/205 barSubplate-4 °FInternal Pilot / Internal Drain26.6 lb207 barGray Iron3-PositionHydraulic PressureHydraulic Valve Systems Division2-Position100 Gal/minDIN w/o PlugPilot Operated Directional Control ValveConsult catalog for other available features24 VDCOmit to Standard ValveOmit - No OptionsNitrileOmit - High Watt140 °F
D61VW001D4NTCF
Backordered
Backordered
POR
EASubplateNFPA D08, CETOP8, DIN NG25, Low Flow, D03 Pilot35-100 GPM3000 psi/205 barSubplate-4 °FInternal Pilot / Internal Drain12.1 kg207 barGray IronAll Ports BlockedHydraulic PressureHydraulic Valve Systems Division2-Position100 Gal/minLeadwire Conduit BoxPilot Operated Directional Control ValveConsult catalog for other available features220-240V AC 50/60HzOmit to Standard ValveOmit - No OptionsNitrileLow Watt140 °F
D61VW001D4NYC
Backordered
Backordered
$1,499.40/each
EASubplateNFPA D08, CETOP8, DIN NG25, Low Flow, D03 Pilot35-100 GPM3000 psi/205 barSubplate-4 °FInternal Pilot / Internal Drain12.1 kg3000 psiGray Iron3-PositionHydraulic PressureHydraulic Valve Systems Division2-Position100 Gal/minLeadwire Conduit BoxPilot Operated Directional Control ValveConsult catalog for other available features120/60 - 110/50 VACOmit to Standard ValveOmit - No OptionsNitrileOmit - High Watt140 °F
D61VW001D4NYCF
Backordered
Backordered
POR
EASubplateNFPA D08, CETOP8, DIN NG25, Low Flow, D03 Pilot35-100 GPM3000 psi/205 barSubplate-4 °FInternal Pilot / Internal Drain12.1 kg3000 psiGray IronAll Ports BlockedHydraulic PressureHydraulic Valve Systems Division2-Position100 Gal/minLeadwire Conduit BoxPilot Operated Directional Control ValveConsult catalog for other available features120/60 - 110/50 VACOmit to Standard ValveOmit - No OptionsNitrileLow Watt140 °F
D61VW001D4NYCF20
Backordered
Backordered
POR
EASubplateNFPA D08, CETOP8, DIN NG25, Low Flow, D03 Pilot35-100 GPM3000 psi/205 barSubplate-4 °FInternal Pilot / Internal Drain26.6 lb3000 psiGray IronAll Ports BlockedHydraulic PressureHydraulic Valve Systems DivisionDetent100 Gal/minLeadwire Conduit BoxPilot Operated Directional Control ValveConsult catalog for additional features.120/60 - 110/50 VACOmit to Standard ValveFast ResponseNitrileLow Watt140 °F
D61VW001D4NYCF3K
Backordered
Backordered
POR
EASubplateNFPA D08, CETOP8, DIN NG25, Low Flow, D03 Pilot35-100 GPM3000 psi/205 barSubplate-4 °FInternal Pilot / Internal Drain12.1 kg3000 psiGray IronAll Ports BlockedHydraulic PressureHydraulic Valve Systems DivisionDetent100 Gal/minLeadwire Conduit BoxPilot Operated Directional Control ValveConsult catalog for additional features.120/60 - 110/50 VACOmit to Standard ValvePilot Choke Meter-out w/ Stroke Adjust A and B EndNitrileLow Watt140 °F
D61VW001D4NYG3S
Backordered
Backordered
$2,157.96/each
EASubplateNFPA D08, CETOP8, DIN NG25, Low Flow, D03 Pilot35-100 GPM3000 psi/205 barSubplate-4 °FInternal Pilot / Internal Drain12.1 kg3000 psiGray Iron4-WayHydraulic PressureHydraulic Valve Systems DivisionDetent100 Gal/minPlug-in Conduit BoxPilot Operated Directional Control ValveConsult catalog for additional features.120/60 - 110/50 VACOmit to Standard ValvePilot Choke Meter OutNitrileOmit - High Watt140 °F
D61VW001D4NYGF456
Backordered
Backordered
POR
EASubplateNFPA D08, CETOP8, DIN NG25, Low Flow, D03 Pilot35-100 GPM3000 psi/205 barSubplate-4 °FInternal Pilot / Internal Drain12.1 kg3000 psiGray IronAll Ports BlockedHydraulic PressureHydraulic Valve Systems Division2-Position100 Gal/minPlug-in Conduit BoxPilot Operated Directional Control ValveConsult catalog for other available features120/60 - 110/50 VACCSAManaplug (Mini) with LightsNitrileLow Watt140 °F
D61VW001D4NYGF5
Backordered
Backordered
POR
EASubplateNFPA D08, CETOP8, DIN NG25, Low Flow, D03 Pilot35-100 GPM3000 psi/205 barSubplate-4 °FInternal Pilot / Internal Drain26.6 lb207 barGray Iron3-PositionHydraulic PressureHydraulic Valve Systems Division2-Position100 Gal/minPlug-in Conduit BoxPilot Operated Directional Control ValveConsult catalog for additional features.120/60 - 110/50 VACOmit to Standard ValveSignal LightsNitrileLow Watt140 °F
D61VW001D4NYPF
Backordered
Backordered
POR
EASubplateNFPA D08, CETOP8, DIN NG25, Low Flow, D03 Pilot35-100 GPM3000 psi/205 barSubplate-4 °FInternal Pilot / Internal Drain12.1 kg3000 psiGray Iron4-WayHydraulic PressureHydraulic Valve Systems DivisionDetent100 Gal/minDIN with PlugPilot Operated Directional Control ValveConsult catalog for other available features120/60 - 110/50 VACOmit to Standard ValveOmit - No OptionsNitrileLow Watt140 °F
D61VW001D4NYW
Backordered
Backordered
$1,464.12/each
EASubplateNFPA D08, CETOP8, DIN NG25, Low Flow, D03 Pilot35-100 GPM3000 psi/205 barSubplate-4 °FInternal Pilot / Internal Drain26.6 lb3000 psiGray Iron4-WayHydraulic PressureHydraulic Valve Systems Division2-Position100 Gal/minDIN w/o PlugPilot Operated Directional Control ValveConsult catalog for other available features120/60 - 110/50 VACOmit to Standard ValveOmit - No OptionsNitrileOmit - High Watt140 °F
D61VW001D4VJP5
Backordered
Backordered
$1,653.96/each
EASubplateNFPA D08, CETOP8, DIN NG25, Low Flow, D03 Pilot35-100 GPM3000 psi/205 barSubplate-4 °FInternal Pilot / Internal Drain26.6 lb207 barGray IronAll Ports BlockedHydraulic PressureHydraulic Valve Systems Division2-Position100 Gal/minDIN with PlugPilot Operated Directional Control ValveConsult catalog for other available features24 VDCOmit to Standard ValveSignal LightsFlurococarbonOmit - High Watt140 °F