PRH102K50 - Pilot Operated Pressure Reducing Valves

Parker’s pilot operated pressure reducing valves are capable of flows up to 150 lpm (40 gpm) and regulating pressures up to 350 bar (5000 psi) and are commonly used for setting the pressure of a sub-circuit within a hydraulic system.
Manufacturer: Parker
Availability:
Backordered
Estimated Lead Time: 71 days
Partner Available:Backordered
SKU PRH102K50
$81.56/each
Ship to
*
*
Shipping Method
Name
Estimated Delivery
Price
No shipping options
Products specifications
Attribute nameAttribute value
UOMEAAdjustment MechanismKnob
Seal MaterialD-Ring (Standard)Flow Rate15 GAL/MIN, 56.3 L/MIN
Pressure Control Range1200-5000 PSI, 82.8-350 BARActuation TypePressure Sensing
Operating Temperature-37 to +93 °CConfigurationPressure Reducing
Filter Efficiency RatingISO 4406 18/16/13, SAE Class 4Weight0.5 lb
Maximum Operating Pressure5000 psiDivisionHydraulic Systems Division
Body MaterialN/AInstallation Torque69-75 Nm
Operation TypeAutomaticMounting TypeScrew in cartridge valve
Adjustment MechanismKnobCavity SizeC10-3
Minimum Operating Temperature-37 °CPressure Control Range1200-5000 psi
Flow Rate56.3 L/minMaximum Kinematic Viscosity45-2000 SSU (6 to 420 cSt)
Pressure Control Sensitivity137.6 per turn barFunctionPilot Operated
Maximum Tank Pressure5000 psiMaximum Inlet Pressure Rating380 bar
For Fluid TypeMineral-based or synthetic hydraulic fluidsMaximum Drain Flow Rate0.94 L/min
DivisionHydraulic Cartridge Systems DivisionStandard Setting Pressure172.4 bar
Maximum Operating Temperature+200 °FValve MaterialAll parts steel. All operating parts hardened steel.
Maximum Pressure Setting5000 psiSeal MaterialD-ring (Standard)
Maximum Flow Rate56.3 L/min
Product resources