SVH101T10N - Pilot Operated Sequence Valves

Parker’s pilot operated sequence valves can be internally or externally piloted to allow multiple actuators to work in sequence based on pressure settings; working with flows up to 152 lpm (40 gpm) and pressures up to 380 bar (5500 psi).
Manufacturer: Parker
Availability:
Backordered
Estimated Lead Time: 71 days
Partner Available:Backordered
SKU SVH101T10N
$101.79/each
Ship to
*
*
Shipping Method
Name
Estimated Delivery
Price
No shipping options
Products specifications
Attribute nameAttribute value
UOMEASeal MaterialNitrile
Pilot OptionInternalDrain OptionExternal
Adjustment TypeTamper ResistantRated Flow (gpm)15
Cracking Pressure (psi)N/APressure Range Adjustment (psi)300-1000
Flow Rate15 Gal/minPressure Control Sensitivity285 per turn psi
Pressure Control Range6.9-69 barMounting TypeThreaded Cartridge Valve
Drain OptionExternalFilter Efficiency RatingISO 4406 18/16/13, SAE Class 4
Actuation TypePressure SensingMaximum Kinematic Viscosity45-2000 SSU (6 to 420 cSt)
Operating Temperature-30 to +250 °FMaximum Operating Pressure380 bar
Body MaterialN/APilot LocationInternal
Weight1 lbReseat Pressure90% of set pressure
DivisionHydraulic Systems DivisionInstallation Torque69-75 Nm
Standard Setting Pressure34.5 barMaximum Drain Flow Rate0.25 L/min
Leak Rate82 @ 3000 PSI (210 BAR) cm3/minMaximum Operating Temperature+121 °C
For Fluid TypeMineral-based or synthetic hydraulic fluidsMaximum Pressure Setting69 bar
DivisionHydraulic Cartridge Systems DivisionMaximum Flow Rate56.3 L/min
Seal MaterialNitrileValve MaterialAll parts steel. All operating parts hardened steel
Maximum Tank Pressure5000 psiFunctionPilot Operated Sequence
Maximum Inlet Pressure Rating380 barPort SizeN/A
Cracking PressureN/A psiAdjustment MechanismTamper Resistant
Cavity SizeC10-3Minimum Operating Temperature-30 °F
Product resources