MHC-010-VJND-00B - Standard Pilot Vented Load Control Valves

Parker’s vented load control valves are designed to operate independent of downstream pressure to prevent runaway loads under all dynamic conditions, handling pressures up to 350 bar (5000 psi) and flows up to 113 lpm (30 gpm).
Manufacturer: Parker
Availability:
Backordered
Estimated Lead Time: 71 days
Partner Available:Backordered
SKU MHC-010-VJND-00B
$272.31/each
Ship to
*
*
Shipping Method
Name
Estimated Delivery
Price
No shipping options
Products specifications
Attribute nameAttribute value
UOMEASeal MaterialNitrile
Port Sizen/aMounting TypeThreaded Cartridge Valve
Holding Pressure1000 PSI, 69 BARMaximum Flow Rate10 GAL/MIN, 37.5 L/MIN
Pilot Pressure Ratio10:1Adjustment MechanismShimmed (non-adjustable)
Pressure Control RangeN/AValve MaterialAll parts steel. All operating parts hardened steel
Seal MaterialNitrileLeak Rate5 @ 80% of setting drops/min
Maximum Operating Temperature+250 °FMaximum Inlet Pressure Rating350 bar
Maximum Flow Rate37.5 L/minDivisionHydraulic Cartridge Systems Division
For Fluid TypeMineral-based or synthetic hydraulic fluidsCavity SizeCDD-1010
FunctionCounterbalance ValvePort SizeN/A
Flow DirectionCylinder port 2, Valve port 3, Pilot port 1Pressure Control RangeN/A bar
Holding Pressure69 barPressure Control SensitivityN/A bar
Flow Rate37.5 L/minMaximum Kinematic Viscosity45-2000 SSU (6 to 420 cSt)
Operating Temperature-30 to +250 °FMinimum Operating Temperature-30 °F
Mounting TypeThreaded Cartridge ValveAdjustment MechanismShimmed (non-adjustable)
Installation Torque50-55 lb-ftPilot Pressure Ratio10:1
DivisionHydraulic Systems DivisionMaximum Operating Pressure350 bar
Weight0.88 lbBody MaterialN/A
Pilot LocationExternalActuation TypePilot Operated, Vented
Filter Efficiency RatingISO 4406 18/16/13, SAE Class 4