MHC-010-SJNK-00B - Standard Pilot Assisted Load Control Valves

Parker’s piloted load control valves are designed to operate independent of downstream pressure to prevent runaway loads under dynamic conditions using a pilot signal, handling pressures up to 420 bar (6000 psi) and flows up to 350 lpm (90 gpm).
Manufacturer: Parker
Availability:
Backordered
Estimated Lead Time: 54 days
Partner Available:Backordered
SKU MHC-010-SJNK-00B
$127.46/each
Ship to
*
*
Shipping Method
Name
Estimated Delivery
Price
No shipping options
Products specifications
Attribute nameAttribute value
UOMEASeal MaterialNitrile
Port Sizen/aMounting TypeThreaded Cartridge Valve
Maximum Flow Rate10 GAL/MIN, 37.5 L/MINPilot Pressure Ratio10:1
Holding Pressure5000 PSI, 350 BARAdjustment MechanismShimmed (non-adjustable)
Pressure Control RangeN/APort SizeN/A
Flow DirectionCylinder port 2, Valve port 3, Pilot port 1FunctionCounterbalance Valve
Seal MaterialNitrileMaximum Inlet Pressure Rating350 bar
Pressure Control RangeN/A psiMounting TypeThreaded Cartridge Valve
Holding Pressure350 barPressure Control SensitivityN/A psi
Flow Rate37.5 L/minAdjustment MechanismShimmed (non-adjustable)
Cavity SizeCDD-1010Minimum Operating Temperature-34 °C
DivisionHydraulic Systems DivisionInstallation Torque68-75 Nm
Body MaterialN/APilot LocationExternal
Weight0.38 kgOperating Temperature-30 to +250 °F
Maximum Operating Pressure5000 psiActuation TypePilot Operated
Filter Efficiency RatingISO 4406 18/16/13, SAE Class 4Maximum Kinematic Viscosity45-2000 SSU (6 to 420 cSt)
DivisionHydraulic Cartridge Systems DivisionValve MaterialAll parts steel. All operating parts hardened steel
Maximum Flow Rate37.5 L/minLeak Rate5 @ 80% of setting drops/min
Maximum Operating Temperature+121 °CFor Fluid TypeMineral-based or synthetic hydraulic fluids
Pilot Pressure Ratio10:1